Products & materials

PCM plates, rods and modules for heat and cold storage

From PCM rods for compatible tanks to storage plates, stacked thermal cores and containerized modules: choose thermal storage at the scale your application needs. Match the product form and system configuration to operating temperatures and conditions.

UltraST PCM conductive network and solid–liquid phase-change cycle
UltraST PCM phase-change heat transferThe conductive network accelerates heat transfer while the PCM absorbs heat and melts, then releases heat and solidifies in its target range. Animation is conceptual; actual behaviour varies by grade and operating conditions.

From a PCM plate to a storage module.

The plate stores energy, the core brings plates together, and the enclosure houses the integrated system. Choose the level that fits your target temperature and operating conditions.

  1. PCM storage plate

    Phase-change material is encapsulated in a plate to store and release cooling or heat within its specified temperature range.

  2. Stacked thermal core

    Multiple plates form an array matched to the heat-transfer structure and flow paths.

  3. Containerised storage unit

    The core is housed in an enclosure and connected to heat exchange, circulation and control systems for the project.

Horizontally stacked PCM plates with water flowing parallel to the plate surfaces
Plate surfaces run parallel to the water flow through the channels; the final layout is project-specific.

Cold-chain transport

Faster thermal response. More time for your cargo.

UltraST combines a conductive composite network, shape stability and latent heat: heat reaches the material faster, cooling fits within limited packaging space, and liquid leakage paths are reduced. High-enthalpy, low-supercooling material selection matches storage capacity and conditioning temperature; validate heat transfer in the actual box, pallet shipper or vehicle.

One test. Two samples, side by side.

Later means more temperature margin

Cargo first exceeds 6°C

UltraST sample39.6 h
Reference ice pack28.2 h

11.4 h later · about +40%

Less time means faster initial cooling

Box air first falls below 8°C

UltraST sample10.2 min
Reference ice pack26.4 min

16.2 min less waiting · about −61%

Both sets contain 3.21 kg net PCM

Gross mass of three modules

UltraST sample3.93 kg
Reference ice pack4.11 kg

Volume of three modules

UltraST sample5.17 L
Reference ice pack5.67 L

Mass −4.4% · volume −8.8%

Source: 5°C cold-chain PCM comparison report, March 2026, pp. 5, 8 and 9. Ambient 12°C; 45 L insulated boxes; three plates and 3.21 kg PCM per set; cargo probe inside a water bottle. 6°C is this comparison's threshold, not a universal compliance limit. Results apply to the tested samples and conditions, not every T3/T5 variant or transport route.

Selection and turnaround: validate the complete pack-out

Faster tempering before use
Time to warm to 0°C was 57.0 vs 129.5 min, from different starting temperatures of −15.8°C and −8.5°C. This is tempering, not recharge time. Daily turns and inventory costs require the full delivery, return and charging cycle.
Shape stability reduces liquid leakage risk
The solid-state composite reduces pathways for liquid seepage. Packaging still requires seal, drop and puncture validation. Food and pharmaceutical use must be assessed for the specific product and certification scope.
Match the route, not only box capacity
Provide cargo temperature limits, ambient profile, journey duration, payload, opening frequency and charging conditions. Passive Edge supplies materials, modules and data; box or vehicle partners integrate and validate the complete system.
Back to cold storage and logistics
Related resources

PCM-35-175-R02

R02 PCM heat and cold storage rod

Your existing tank. More thermal storage.

Add phase-change storage to a compatible existing tank without replacing it or altering its circuit. R02 rods are loaded through an existing opening and store and release heat or cold within a matched temperature range, supporting home heat pumps and emergency liquid cooling at edge sites.

Bring thermal storage into your existing system

Keep the tank and circuit

Load rods through a suitable existing opening and use the installed tank and coils.

More storage in the same space

Match the PCM to charging and discharging temperatures to add latent heat or cold storage capacity.

Heat transfer, separate fluids

The rods and tank liquid form the storage side; the original system fluid circulates independently in closed coils.

Phase-change temperature options

  • 7 °C
  • 10 °C
  • 32 °C
  • 40 °C
  • 50 °C
  • 58 °C
  • 65 °C

Select a phase-change temperature for the system’s charging and discharging range.

Two applications. One storage approach.

A Western male homeowner inserts an R02 rod horizontally through an existing lower side opening in a home heat-pump tank.

Home heat-pump tank upgrade

Load through a suitable existing side opening to add storage for home heating and hot water, retaining the tank and pipework.

Telecom edge liquid-cooling rack connected to a backup cold-storage tank, cut away to show randomly packed R02 rods, tank liquid and isolated coils.

Emergency liquid cooling for edge sites

Store cold during normal operation. During an interruption or switchover of the main cooling source, release it as a short cooling buffer while circulation remains available.

White heat-pump tank cutaway with randomly packed R02 rods and separate closed coils.

Heat exchange through isolated coils

Loose-packed rods and tank liquid form the storage side. Heat passes through closed coils while the system fluid stays separate.

Product and application images are renders.

Match storage to your tank

For tanks with existing coils, a suitable opening and sufficient internal clearance. Share tank volume, opening size, coil layout, charging and discharging temperatures and target capacity so we can match the material, rod count and heat-transfer conditions.

R02 thermal storage rod brochure

V1.1 · PDF · 中文 / English / Deutsch

Specifications, applications and selection guidance. Choose a language to request the brochure by email.

Request by email · EnglishRequest by email · 中文Request by email · Deutsch
02 / Standard Plate Catalog

Standard plates by product line and phase-change temperature.

Building Comfort Standard Plate

edge comfort Indoor Temperature Control Module

Solid-state PCM standard plates for ceiling cavities, window-side cabinets, and interior assemblies, reducing daily temperature swings and improving indoor comfort.

300 × 300 mm · T3 30 / T5 50 mm · six phase-change temperatures, 22–32 °C · 0.154–0.257 kWh/plate

edge comfort PCM standard plate ceiling installation
PE-DC-CS

Data Center Cold Storage

5–32 °C, for chilled-water buffering, peak shifting, and cooling-loop stabilization.

Data-center PCM cooling plate and core
Data-center PCM cooling plate and corePlate concept; enclosure, dimensions and temperature range depend on the selected model.
Phase-change temperatureEnergy per plate (kWh)Request
5 °C0.281-0.397 kWhEmail request
7 °C0.274-0.434 kWhEmail request
10 °C0.261-0.460 kWhEmail request
12 °C0.274 kWhEmail request
15 °C0.274-0.493 kWhEmail request
17 °C0.274 kWhEmail request
18 °C0.289-0.483 kWhEmail request
20 °C0.279-0.500 kWhEmail request
21 °C0.279 kWhEmail request
22 °C0.263-0.403 kWhEmail request
23 °C0.286 kWhEmail request
24 °C0.286-0.556 kWhEmail request
25 °C0.286 kWhEmail request
26 °C0.286-0.559 kWhEmail request
27 °C0.286 kWhEmail request
28 °C0.286 kWhEmail request
30 °C0.251-0.561 kWhEmail request
32 °C0.247 kWhEmail request
PE-LNG

LNG Cold-Energy Recovery

Negative phase-change temperatures, for LNG cold-source recovery and low-temperature process buffering.

Phase-change temperatureEnergy per plate (kWh)Request
−39 °C0.535 kWhEmail request
−24 °C0.400 kWhEmail request
−21 °C0.495 kWhEmail request
−19 °C0.416 kWhEmail request
−15 °C0.394 kWhEmail request
−10 °C0.408 kWhEmail request
−5 °C0.435 kWhEmail request
PE-HT

Heat Storage

Published phase-change temperatures for heating, waste-heat recovery, and process thermal management.

Phase-change temperatureEnergy per plate (kWh)Request
49 °C0.255 kWhEmail request
58 °C0.521 kWhEmail request
61 °C0.254 kWhEmail request

This page summarizes published material and module data. Entries marked for technical confirmation require further review; use the relevant product data sheet and project confirmation for final selection. Request product manuals by email. Edge Comfort documents are available to download directly.

03 / Cooling Cabins

Cooling cabins for project-scale deployment.

Data Center Cooling Cabin

Series-level S-type cooling cabin manuals covering all published 5-32 °C PE-DC-CS phase-change temperatures, with capacity, water sensible energy, and discharge power calculated on one unified S-type basis.

PE-DC-CS-S SERIES · 18 phase-change temperatures, 5-32 °C · 347-680 kWh · up to 2.34 MW · S-type 2.8 × 2.3 × 2.3 m

Data-center standard cooling cabin installation

Tell us what you need.

Start with a temperature problem, a material need or a collaboration idea. You can get in touch before technical details are known.

Discuss a collaboration