PCM Product Library

PCM thermal storage products

Materials, standard plates, modules, and cooling cabins for cold-chain, building, data-center, LNG, and heat-recovery projects.

Materials · Standard plates · Modules · Cooling cabins

Data-center standard cooling cabin
01 / Material Library

Materials by type and phase temperature.

Cold Storage Materials

Negative to 32 °C PCM

For cold chain, data-center chilled water, LNG cold recovery, and summer building buffering — inorganic, organic, and composite systems.

Heat Storage Materials

42 to 120 °C PCM

For heating, waste-heat recovery, process thermal buffering, and high-temperature-side thermal management.

Material Form

Bulk PCM

Standard Pure PCM entries; engineering data is published in the per-phase-point TDS.

Material Form

Nano / Microencapsulated PCM

Engineered encapsulation for composites, coatings, slurries, and micro/nano encapsulated cold-storage products.

02 / Standard Plate Catalog

Standard plates by product line and phase point.

PE-DC-CS

Data Center Cold Storage

5–32 °C, for chilled-water buffering, peak shifting, and cooling-loop stabilization.

Phase pointLatent capacity / plateChemistryManual
5 °C0.289–0.379 kWhInorganic · Organic · CompositePDF
7 °C0.278–0.397 kWhInorganic · Organic · CompositePDF
10 °C0.267–0.424 kWhInorganic · Organic · CompositePDF
12 °C0.278–0.424 kWhInorganic · Organic · CompositePDF
15 °C0.278–0.442 kWhInorganic · Organic · CompositePDF
17 °C0.278 kWhOrganicPDF
18 °C0.289–0.460 kWhInorganic · Organic · CompositePDF
20 °C0.283–0.451 kWhInorganic · OrganicPDF
21 °C0.283 kWhOrganicPDF
22 °C0.267–0.361 kWhInorganic · OrganicPDF
23 °C0.289 kWhOrganicPDF
24 °C0.289–0.469 kWhInorganic · Organic · CompositePDF
25 °C0.289 kWhOrganicPDF
26 °C0.289–0.478 kWhInorganic · OrganicPDF
27 °C0.289 kWhOrganicPDF
28 °C0.289–0.361 kWhInorganic · OrganicPDF
30 °C0.244–0.361 kWhInorganic · OrganicPDF
32 °C0.244 kWhOrganicPDF
PE-LNG

LNG Cold-Energy Recovery

Negative phase points, for LNG cold-source recovery and low-temperature process buffering.

Phase pointLatent capacity / plateChemistryManual
−57 °C0.361 kWhInorganicPDF
−42 °C0.361 kWhInorganicPDF
−25 °C0.361 kWhInorganicPDF
−24 °C0.433 kWhInorganicPDF
−22 °C0.361 kWhInorganicPDF
−21 °C0.560 kWhInorganicPDF
−19 °C0.506 kWhInorganicPDF
−15 °C0.487 kWhInorganicPDF
−10 °C0.515 kWhInorganicPDF
−5 °C0.487 kWhInorganicPDF
PE-HT

Heat Storage

Phase points above 42 °C, for heating, waste-heat recovery, and process thermal management.

Phase pointLatent capacity / plateChemistryManual
42 °C0.244–0.361 kWhInorganic · OrganicPDF
46 °C0.361 kWhInorganicPDF
48 °C0.379 kWhInorganicPDF
49 °C0.244–0.361 kWhInorganic · OrganicPDF
53 °C0.244–0.361 kWhInorganic · OrganicPDF
56 °C0.361 kWhInorganicPDF
58 °C0.244–0.515 kWhInorganic · OrganicPDF
61 °C0.244 kWhOrganicPDF
73 °C0.289 kWhOrganicPDF
120 °C0.311 kWhOrganicPDF

Data source: active Pure PCM standard products in the Passive Edge PCM cost system plus active RD standard enthalpy values. Capacity values in the manuals are design estimates and must be engineering-qualified before project deployment.

03 / Modules & Cooling Cabins

Modules and cooling cabins for project deployment.

Building Comfort Module

edge comfort Passive PCM Thermal Buffer System

Solid-state PCM modules for ceiling cavities, window-side cabinets, and interior assemblies, reducing daily temperature swings and improving indoor comfort.

300 × 300 mm · T3 30 / T5 50 mm · six phase points, 22–32 °C · 0.154–0.257 kWh/module

edge comfort PCM module ceiling installation
Data Center Cooling Cabin

Standard S-type cooling cabin using 7C micro/nano encapsulated composite PCM for AI data-center chilled-water buffering and short peak windows.

PE-DC-CS-07C-S-COM · 544 kWh · approx. 1.87 MW · S-type 2.8 × 2.3 × 2.3 m

Data-center standard cooling cabin installation